Characteristics of ST-gel
ST-gel has various characteristics to satisfy customers' needs. Taking advantage of each characteristic, the products can be used in various fields for many different applications.

Customizing
ST-gel allows the customization of its physical properties such as adhesiveness and conductivity, and it can also be processed together with other materials such as cloth and polyurethane foam.
We not only sell gel materials with a high level of safety but also design the product and carry out final product processing to provide the most suitable ST-gel according to customers' needs.

Adhesiveness
Adhesiveness can be adjusted from a high level of adhesiveness similar to bioadhesive tape to low adhesiveness.

Conductivity
Can be made conductive by adding electrolytes to the gel. Can be adjusted from low impedance for biosensors such as electrocardiograms to high impedance for electrical stimulation devices such as TENS and EMS.
Moisture Respirability
ST-gel has the properties of releasing moisture in a dry environment and absorbing moisture in a humid environment. Therefore, it can be designed to not get dry or not to swell up in everyday environments.

Safety
The amount of residual monomers, which may become the cause of irritation or skin disorders, is reduced by controlling the reactivity when manufacturing the ST-gel. Moreover, because the component ingredients have all been confirmed safe, a high level of safety is secured.
Widely adopted for various applications such as repeated-use adhesive pads for TENS and EMS, electrodes for wearable devices attached to the skin for extended periods of time, and electrodes for Holter ECGs etc.
When the surface of the tape adhered to the skin is peeled off and treated with iodine, it has been observed that ST-gel has less keratin adhered compared with standard medical tape and so is noticeably more gentle to the skin. (The part that looks white is keratin, and the medical tape has keratin attached to the whole surface.)

Basic Safety
Biocompatibility evaluated based on ISO 10993. * Example of measured values.
Biocompatibility Evaluation Result
Test Details | Test Purposes | ST-gel |
---|---|---|
Cytotoxicity Testing | Toxicity to living organisms | 0 |
Primary Skin Irritation Testing | Irritation to the contacted skin | P.I.I 0.0* |
Sensitization Testing | Allergy occurrence rate | No sensitizing properties |
Determination of rash conditions on human skin
Kawai's Method 24-hour Open Patch Test 3B-0C-OD
It is said that general adhesive tapes tend to cause rashes and the occurrence of C-Stage and D-Stage cannot be avoided, but ST-gel has been determined to impose less chance of causing irritation to human skin.
- Test Method
-
- The test material is patched onto the inner part of the upper arm of 20 test subjects.
- After the material is patched for 24 hours, the attachment site is examined and replica specimens are collected only from those not showing any abnormalities visible to the naked eye.
- The entire visual field of replica specimens is microscopically observed at 50 times magnification.
- Observed and determined by classifying into 4 stages from A-Stage to D-Stage according to irritation severity.
Kawai Method 24 Hour Open Patch Test 3B-0C-OD
Evaluation Method | Microscopic Evaluation | Naked Eye Evaluation | |||||
---|---|---|---|---|---|---|---|
Skin Surface Morphological Changes | Round ridges | Depressed skin grooves |
|
|
|||
Irritation Rank | - | (Test Subject Irritation Index)-(Control Irritation Index) | 1 case or more | 1 case or more | |||
≦0 | 1~2 | 3 | ≧4 | ||||
Negative | Mostly negative | Mostly negative | Positive | Positive | Positive | ||
Irritation Rank | A-Stage | B-Stage | C-Stage | D-Stage | |||
High
Low
|

replica image



Grade
Grade | Characteristics | Application Examples |
---|---|---|
SR | Repeated adhesiveness | Electrodes for Transcutaneous Electrical Nerve Stimulation (TENS), Adhesive Pads for Electrical Muscle Stimulation (EMS) |
CR | Low impedance | Electrocardiogram (ECG) Electrodes, Biosensors |
NR | Low aluminum corrosive | Return Electrodes for Electrosurgical Instruments |
HIT | High initial adhesiveness immediately after being adhered | Electrodes for Examination/Electrocardiogram |
AG | Even if it is made thin, it is highly adhesive | Adhesive Tapes |
G | Elasticity, Slight adhesiveness | Low Adhesive Sheets, Temporary Anchoring Materials |
CP | High wetness and medicinal ingredients can be added | Skin Care Pack (Cosmetics, Quasi-drugs) |
List of Application Examples
Can be customized based on customers' requests. Other than the sales of gel materials, the gel has been widely adopted for various applications such as the OEM of cosmetic gel masks and various processed electrode products.
Materials Field | Medical Field | Healthcare Field | Cosmetic Field |
---|---|---|---|
|
|
|
|
![]() |
![]() |
![]() |
![]() |
Quality Control
We have acquired ISO 9001, ISO 13485, and 14001 certifications. We are implementing consistent manufacturing management from procurement of the ST-gel raw materials to manufacturing, inspections and shipments in order to achieve stable quality control.