Site map | Japanese site
Please read.
TOP Gel sheet materials Medical care Health Beauty New applications Safety
Medical care
Summary
ECG electrodes
Stimulation electrodes
Gel processed item
Contact information
Q & A
Inquiry form
n Chemicals Sales group
phone: +81-3-3347-9617

ECG electrodes

These electrodes can be used in electrocardiography for patients from newborns babies to adults.
The following electrodes are available, with a range of shapes, surface materials, and hook terminals.
The gel is kind to the skin, non-irritant and stays moist.
- Full-surface gel monitoring electrodes (for both children and adults)
- Monitoring electrodes which can be penetrated by X-ray (large and small sizes, with adhesion frame)
- Monitoring electrodes with adhesion frames
(foam or cloth, in a range of shapes)
- Electrodes for examinations (resting ECG electrodes)
Characteristics of electrodes for electrocardiography AAMI (Association for the Advancement of Medical Instrumentation) standards Electrode for ECG
using ST-gel
Impedance across electrode pair (Ω) 2000max.avg 150
Voltage across electrode pair (mV) 100max. 0.5
Defibrillation resistance (mV) 100max. 15
Defibrillation resistance (mV/sec) 1max. 0.2
Impedance across electrode pair
after defibrillation resistance test (Ω)
3000max. 130
(These are examples of our measurements for monitoring electrodes with adhesion frames.)


Full-surface gel monitoring electrodes (Ag and AgCl element)

This full-surface gel is designed to prevent skin irritation.
Shape Surface material Features
38 mmΦ Foam material The full-surface gel is designed to be non-irritant, so that electrodes can be reapplied.
23 mmΦ Cloth material


Q & A Inquiry

Monitoring electrodes which can be penetrated by X-rays (Ag and AgCl element)

n Electrodes with full-surface gel

Shape Surface material Features
40 mmΦ Cloth material The 100% gel surface is designed to be non-irritant, so that electrodes can be reapplied.
38 x 19 mm

n Electrodes with gel plus adhesion frame

Shape Surface material Features
40 mmΦ Foam material Prevents disinfectant and blood from penetrating, but transmits X-rays.


Q & A Inquiry

Monitoring electrodes with adhesion frames (gel plus adhesion frame) (Ag and AgCl element)

Shape Features
40 mmΦ These electrodes are available with a range of shapes and surface materials.
40 x 40 mm


Q & A Inquiry


Electrodes for examination (resting ECG electrodes) (Ag and AgCl element)

Shape Features
20 x 20 mm Have high tackiness directly after being applied to the skin.
Can be produced in a variety of shapes.
Other sizes


Q & A Inquiry


Electrodes with lead wire for newborn babies (carbon element)

Shape Connector Cord Number of wires in a cord
40 mmΦ 1.5DIN Carbon
/PVC coating
3
20 mmΦ 3 parallel wires in 1 cord
Characteristics
- Impedance across electrode pair: not more than 20 kΩ
- Voltage across electrode pair: within ±100 mV
Features
The full-surface gel adheres gently to the skin. A cloth material has been used for good air permeability, making the electrodes safe for newborn babies.


Q & A Inquiry

Example of use [by GE Yokogawa Medical System Co., Ltd.]

n Monitoring electrodes sold to GE Yokogawa Medical System

Electrodes with the "GE Healthcare" logo. The following four types of cardiac potential monitoring electrode are available:

Foam material
Product number Surface material Structure of the adhesive portion
45352V Foam material Gel with adhesion frame
SDC141 Cloth material
SDC112 Cloth material Full-surface gel
SDC113 Foam material


Q & A Inquiry

Summary ECG electrodes Stimulation electrodes Gel processed item
Policy on protecting and using personal information
This home page is provided by Sekisui Plastics Co., Ltd.
Copyright(C)2005 SEKISUI PLASTICS CO., LTD.